排序方式: 共有27条查询结果,搜索用时 15 毫秒
21.
Nabil Ben Omar Manuel Entrena MaTeresa González‐Muñoz José Maria Arias Francisco Huertas Manuel Rodriguez‐Gallego 《毒物与环境化学》2013,95(1-4):209-217
We studied the morphological diversity of struvite crystals produced by Myxococcus coralloides and Myxococcus xanthus in different culture conditions. We discussed the similarities of these crystals with the struvite morphology studied previously following the theory of the periodic bond chains. 相似文献
22.
Charbel José Chiappetta Jabbour Eliciane Maria da Silva Ely Laureano Paiva Fernando Cesar Almada Santos 《Journal of Cleaner Production》2012,21(1):11-22
Current studies indicate a need to integrate environmental management with manufacturing strategy, including topics like cross-functional integration, environmental impact, and waste reduction. Nevertheless, such studies are relatively rare, existing still a need for research in specific regional contexts. At the same time, the results found are not unanimous. Due to these gaps, the objective of this article is to analyze if environmental management can be considered a new competitive priority for manufacturing enterprises located in Brazil. A cross-sectional survey was conducted with Brazilian companies certified by ISO 14001. Sixty-five valid questionnaires were analyzed through Structural Equation Modelling (SEM). The first conclusion is that environmental management presents a preventive approach in the sample analyzed, focused on eco-efficiency, what potentially do not to create a competitive advantage. This preventive approach inhibits environmental management from being regarded as a new competitive manufacturing priority, in the full sense as defined by the literature. Another important result is that environmental management, although following a preventive focus, may influence positively the four manufacturing priorities: cost, quality, flexibility and delivery. 相似文献
23.
E. Gallego F.J. Roca J.F. Perales G. Sánchez P. Esplugas 《Waste management (New York, N.Y.)》2012,32(12):2469-2481
Municipal solid waste treatment facilities are generally faced with odorous nuisance problems. Characterizing and determining the odorous charge of indoor air through odour units (OU) is an advantageous approach to evaluate indoor air quality and discomfort. The assessment of the OU can be done through the determination of volatile organic compounds (VOCs) concentrations and the knowledge of their odour thresholds. The evaluation of the presented methodology was done in a mechanical–biological waste treatment plant with a processing capacity of 245.000 tons year?1 of municipal residues. The sampling was carried out in five indoor selected locations of the plant (Platform of Rotating Biostabilizers, Shipping warehouse, Composting tunnels, Digest centrifugals, and Humid pre-treatment) during the month of July 2011. VOC and volatile sulphur compounds (VSCs) were sampled using multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and Tenax TA tubes, respectively, with SKC AirCheck 2000 pumps. The analysis was performed by automatic thermal desorption (ATD) coupled with a capillary gas chromatography (GC)/mass spectrometry detector (MSD). One hundred and thirty chemical compounds were determined qualitatively in all the studied points (mainly alkanes, aromatic hydrocarbons, alcohols, aldehydes, esters, and terpenes), from which 86 were quantified due to their odorous characteristics as well as their potentiality of having negative health effects. The application of the present methodology in a municipal solid waste treatment facility has proven to be useful in order to determine which type of VOC contribute substantially to the indoor air odorous charge, and thus it can be a helpful method to prevent the generation of these compounds during the treatment process, as well as to find a solution in order to suppress them. 相似文献
24.
Tomás?Landete-CastillejosEmail author Christian?Gortázar Joaquin?Vicente Yolanda?Fierro Andres?Garcia Laureano?Gallego 《Behavioral ecology and sociobiology》2004,57(1):1-8
Several theories predict offspring biases towards males or females with increasing reproductive resources of the mother to maximize reproductive returns by offspring, or as a result of prohibitive cost of the most expensive sex for young mothers or those in poor condition. This study examines foetus sex of 221 harvested hinds in a food-supplemented game estate for 10 years, according to hind age class (yearlings, subadults or adults), precise age, body mass and condition, and jaw length. A logistic model showed that hinds had a greater probability of bearing a male foetus with increasing age class, but not with any other variable. The greatest bias was found in yearling hinds. After controlling for age class and mass, jaw length was smaller in pregnant compared to non-pregnant yearlings and subadults, which suggests a trade-off between reproduction and growth. The bias towards females in yearlings increased as gestation proceeded, which suggests that the bias might be a result of selective abortion of male foetuses. Although results do not exclude an investment in males to increase number of grand-offspring, they suggest that young hinds may produce daughters as a trade-off between low energetic-cost offspring and their need to grow.Communicated by S. Krackow 相似文献
25.
Gallego E 《Journal of environmental radioactivity》2006,85(2-3):247-264
A model is presented for the migration of 137Cs in the urban environment, including the drainage systems and the sewage treatment plants, with flexibility to be adapted to different configurations common in urban areas. The dynamics of 137Cs is simulated both under natural evolution and in case of forced decontamination, which can have a direct impact on the radioactivity going to sewers. The model assesses the activity concentrated in sewage sludge and that discharged with the treated or untreated effluent to the receiving watercourse. Tests made for two post-Chernobyl contamination scenarios in Sweden show differences between model predictions and observed results within the range of the experimental uncertainties. An uncertainty and sensitivity analysis of the main model parameters indicates that some parameters may have a significant influence on the results of the model. Moreover, the model uncertainty is driven by a few parameters; therefore, additional research could be necessary into these parameters, aiming at simplifying the model without losing its predictive power. 相似文献
26.
Investigation of trace element sources from an industrialized area (Avilés, northern Spain) using multivariate statistical methods 总被引:2,自引:0,他引:2
In the industrialized urban area of Avilés (Spain), pooled soil samples from grassland sites were taken after careful sampling design and then investigated for their content of trace elements. A combination of statistic and geostatistic techniques proved to be a reliable tool in the interpretation of the analytical results. Geochemical groups and areas influenced mainly by anthropogenic activities were distinguished by means of classic multivariate methods (factor analysis and cluster analysis) and innovative geostatistical tools (Fourier spectral analysis). The constitution of the groups is supported by the linked results of methods sequentially distributed in order to extract as much information as possible from the original data. 相似文献
27.
A methodology for identifying volatile organic compounds (VOC) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of VOC present were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) value was detected in episodes in indoor air (1.33 ( 1.53 mg/m3) compared to outdoor air (0.71 ( 0.46 mg/m3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-metoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be a not declared activity of storage and manipulation of solvents located at the bottom of a contiguous building. 相似文献